2.2. Building Controllers / DSC System Controllers


System Controllers

Delta Controls System Controllers / DSC

DSCs are perfect for controlling critical equipment such as air-handling units or hydronic systems. DSCs provide programming flexibility and include features such as memory backup and a battery- backed, real-time clock. The DSC System Controllers are Native BACnet Building Controllers that communicates on a Twisted Pair 10-BaseT BACnet/IP and BACnet over Ethernet network, or on an RS-485 LAN using the MS/TP BACnet protocol. As the controllers are completely programmable, GCL+ programs and BACnet objects can be tailored to the specific application. Both firmware and controller databases are loadable over the network.Key Features: 

Key Features:
Control Your Network: The real-time clock and memory backup make the DSC ideal for managing your network or controlling critical equipment.
A Flexible Array of Sizes: The DSC comes in an array of sizes. Use it to control small terminal units or to take care of your central plant.

DSC-606E - 6 universal inputs and 6 binary TRIAC outputs, the DxC-606 is suitable for controlling various packaged units and other equipment with low density I/O requirements. 

DSC-633E - 6 universal inputs, 3 binary TRIAC outputs and 3 universal outputs, the DxC-633 is suitable for controlling various packaged units and other equipment with low density I/O requirements.

DSC-1146E - 11 universal inputs, 6 binary TRIAC outputs and 4 Universal (analog) outputs, the DxC-1146 is suitable for controlling various packaged units and other equipment with small I/O requirements.

DSC-1180E - 11 inputs, and 8 Universal (analog) outputs, the DxC-1180 is suitable for controlling various packaged units and other equipment with medium I/O requirements.

DSC-1212E - 12 inputs, 12 outputs, the DxC-1212 is suitable for controlling various packaged units and other equipment with medium I/O requirements.

DSC-1616Edesigned for a wide range of applications requiring no more than 16 inputs and 16 outputs, including but not limited to Roof Top Units, Air Handlers, Boilers or Chillers, etc. A second RS-485 port may be configured as an MS/TP SubLAN or a LINKnet network that supports up to 12 Delta BACstats or other Delta LINKnet controllers. The 16 universal inputs are jumper configurable and the 16 analog outputs come with monitored Hand-Off-Auto (HAO) switches.